Energy Technologies Inc.
Technical Paper

Ash Content Measurement in Coal-Fired Power Generation

A Practical Guide to Dual-Gamma Technology for Online Ash Analysis

Maryville, Tennessee  ·  energytechinc.com  ·  +1 865-927-9330

EN ES

Abstract. Ash content is a major coal quality parameter for power generation. It affects heat rate, slagging and fouling tendency, fly ash disposal cost, and compliance with particulate emission limits. This paper describes the dual-gamma measurement principle used in ETI's Model 410M Ash Analyzer, explains how it differs from laboratory ashing, discusses standalone use for continuous ash measurement and integration with ETI's Model 730 FSEA in a patented combined system delivering direct ash measurement along with full elemental analysis. Guidance on instrument placement, calibration, and integration with plant control systems is also provided. Field experience from installations in the United States is used to illustrate practical applications of continuous online ash measurement.

1. Why Ash Content Matters in Power Generation

Coal ash is the non-combustible residue remaining after combustion. Its main components are silica (SiO₂), alumina (Al₂O₃), iron oxide (Fe₂O₃), calcium oxide (CaO), and magnesium oxide (MgO).

ASTM D3174 defines ash as the residue remaining after ignition under specified conditions. The original mineral matter undergoes chemical transformation during ashing, so measured ash is a test-defined quantity rather than a sum of the original inorganic content. In a coal-fired power plant, ash content affects operations across every major system.

1.1 Heat Rate and Fuel Cost

Higher ash content equals lower heating value. At a constant moisture content and combustible composition, coal with higher ash delivers less combustible material per ton, requiring higher tonnage per hour to maintain a fixed megawatt output and raising fuel cost per MWh generated at an unchanged price per ton.

Variations in moisture content and combustible composition also affect heating value. Continuous measurements of ash, moisture, and heating value allow operators to track changes in coal quality in real time and to adjust process parameters as needed.

1.2 Slagging and Fouling

Coal behavior at combustion temperatures is determined by its mineral composition. Certain combinations of iron, calcium, and alkali compounds lower ash fusion temperatures, forming sticky, low-melting point deposits on furnace walls (slagging) and convective heat transfer surfaces (fouling). Slagging and fouling deposits negatively impact heat transfer efficiency and increase tube metal temperatures. If these deposits are allowed to accumulate, they cause forced outages for cleaning and tube failures.

Online ash measurement enables operators to view ash levels entering the furnace in real time, allowing informed soot blower scheduling and early detection of and reaction to materials which increase slagging risk.

1.3 Fly Ash Disposal and Beneficial Use

Fly ash captured by electrostatic precipitators or fabric filters can result in significant handling and storage costs. However, high-quality fly ash can be sold as a concrete additive, converting a disposal cost into a revenue stream. Marketable fly ash quality can be supported through continuous ash monitoring, allowing operators to make informed decisions to maintain consistent combustion conditions for fly ash generation. Fly ash carbon content and concrete suitability depend on additional factors beyond ash percentage.

1.4 Emission Compliance

Particulate matter emissions from coal combustion are directly related to the ash content of the material being burned and the performance of particulate control equipment. Plants operating under New Source Performance Standards (NSPS) or state implementation plan limits must demonstrate their precipitator or baghouse is operating correctly for the actual ash load.

Continuous ash data is useful for that verification by providing real-time records of the ash load being processed. Emissions compliance itself is dependent upon the collection equipment performance and stack measurements.

2. Methods for Measuring Ash Content

2.1 Laboratory Ashing (ASTM D3174)

ASTM D3174 is the reference method for laboratory ashing, in which a weighed coal sample is heated in a muffle furnace at 700–750°C until all combustible material is oxidized. Ash content as a percentage on a dry basis is determined by dividing the residue mass by the moisture-corrected original sample mass and multiplying by 100.

This method is established and accurate, but it requires approximately 4 hours per sample to process. Therefore, the primary limitation of this method is processing speed. The results are not available in time to make real-time process decisions concerning the material sampled, and they represent the average composition of the sampled lot but do not reflect individual changes in coal quality between sample grabs.

2.2 The Model 410M as a Standalone Ash Analyzer

The Model 410M directly measures ash and weight, providing moisture readings through a density-based moisture module. Calculated heating value is provided from the ash and moisture readings. The instrument bolts to the existing conveyor structure. Measurements are taken continuously, compiled into 3-second readings, and averaged into 1-minute values which are available to plant personnel.

2.3 The ETI Patented Combined System: PGNAA + Dual-Gamma Ash Measurement

The Model 800 Prompt Gamma Neutron Activation Analysis (PGNAA) analyzer accurately measures the elemental content of material on the conveyor belt in real-time. However, there are three critical parameters PGNAA does not measure directly. They are ash content, moisture, and weight. A complete coal quality picture (including a calculated heating value) cannot be derived from PGNAA data alone.

ETI addresses this problem with a patented design combining the Model 800 PGNAA Analyzer with the Model 410M Ash Analyzer, forming the Model 730 Full Stream Elemental Analyzer (FSEA). The combined system continuously measures elemental composition, ash, and material weight while providing calculated measurements of moisture and heating value.

The weight measurement provided by the Model 410M allows the PGNAA system to convert relative elemental concentrations into absolute quantities. Measuring the weight of material inside the analysis zone eliminates the requirement for consistent belt loading and improves analytical accuracy under fluctuating load conditions. The detailed elemental data is used to further correct the ash measurement.

This provides operators with the complete coal-quality picture needed for quality grading, sorting, blending, combustion optimization, and emissions management from a single online system.

3. The Dual-Gamma Measurement Principle

The dual-gamma method measures ash content directly from the differential attenuation of two gamma-ray beams (one low-energy, one high-energy) passing through the full coal stream on the belt.

3.1 Physical Basis

Dual-gamma measurement is based on the attenuation of gamma radiation passing through a material. Attenuation is dependent on both the mass and elemental composition of the material. At higher gamma energies, attenuation is primarily dependent on mass, while lower-energy gamma radiation exhibits greater sensitivity to elemental composition.

3.2 How the Two Sources Work Together

The Cs-137 high-energy gamma emissions are attenuated by the total mass of material on the belt. Its signal is therefore a direct measurement of belt-loading and is largely insensitive to the elemental composition of the material.

The Am-241 low-energy gamma emissions are attenuated by both the total mass on the belt and the principal ash-forming elements. Its signal therefore carries information about both belt loading and ash content.

The system uses the Cs-137 signal to normalize for belt loading while isolating ash content from the Am-241 signal. This means the instrument compensates automatically for belt-loading, enabling operators to run varying belt loads while still receiving accurate ash measurements.

Key Technical Point

The Model 410M directly measures ash through differential gamma attenuation without requiring a separate elemental analyzer.

3.3 The Model 410M Instrument Design

The high and low energy sources are installed in a source holder mounted above the conveyor belt. The source holder is lead-shielded and includes a movable shutter which can be used to block the radiation beam for maintenance and personnel safety. A scintillation detector is installed under the belt opposite the source holder. The detector assembly is temperature-controlled for measurement stability. The scintillation detector produces electrical pulses proportional in amplitude to the gamma energy deposited in the detector. The detector electronics process these pulses to produce an energy spectrum. The system software uses this spectrum to determine ash content and weight and calculate moisture and heating value.

The instrument's electronics enclosure is rated NEMA 4X (mild steel construction) for operating in the dusty and wet conditions of typical coal handling facilities.

3.4 Calibration

The Model 410M is calibrated using coal samples acquired from the site which represent the range of materials to be processed. The materials are analyzed by a certified laboratory using ASTM D3174. The material is then bagged in individual 5-pound (2 Kg) bags and labeled with the customer name and sample batch number to be used as calibration standards.

The calibration standards are used for both the in-house factory calibration and the on-site calibration after installation. They are retained by the customer for future calibration checks.

Three to five calibration samples are required to establish the calibration range. The calibration is specific to the coal source and conveyor characteristics.

ETI engineers perform static calibration during commissioning and later make fine adjustments based on feedback from lab testing. Recalibration is needed when the detector is changed or when the coal characteristics fall outside the calibrated range, for example when a new coal source with significantly different mineralogy is introduced. For applications with a consistent coal supply, recalibration is infrequent.

4. Model 410M Instrument Specifications

Measurement principle
Dual-gamma transmission (differential attenuation)
Measurement precision
±0.5 percentage points of ash (dry-weight basis, per ASTM D3174)
Update rate
3-second internal cycle; 1-minute averages logged to SQL database
Belt loading compensation
Automatic (dual-beam ratio method)
Belt speed compensation
Automatic with belt speed input
Conveyor belt width
Up to 72 inches (custom configurations available)
Analog output
4–20 mA (configurable for all measured parameters)
Digital output
SQL stored procedure (preferred); Modbus TCP/IP
Display software
DataView (Windows-based; trend display, numerical display, alarm management, data logging)
Radiation source
Two sealed sources; customer holds the radioactive material license; ETI supports source logistics
Operating temperature
–30°C to +50°C ambient
Enclosure rating
NEMA 4X (mild steel)
Power
120/240 VAC, 50/60 Hz

5. Installation and Conveyor Placement

5.1 Optimal Measurement Location

The Model 410M should be installed on a conveyor belt carrying a representative load of the coal stream being characterized. The ideal location is:

A single Model 410M on the main reclaim conveyor provides a blended-coal measurement for plants with multiple coal sources feeding separate bunkers. Plants that need to characterize individual coal sources separately should install one instrument per source conveyor.

5.2 Structural Requirements

The Model 410M detector assembly and source holder are mounted on a structural frame supplied by ETI which straddles the conveyor belt. The frame is custom-sized for each conveyor structure. ETI requires dimensional information for the conveyor structure in order to fabricate the frame correctly. ETI provides detailed mounting drawings as part of the installation package.

The instrument requires a conduit run for power (120/240 VAC) and a network cable (Cat5e or better) routed to the electronics enclosure for equipment power and communication. ETI provides all cabling between the electronics enclosure and the belt-mounted unit. However, the customer must provide conduit between the two locations. The electronics enclosure is ideally located in a protected climate-controlled area for maintenance reasons but can be located anywhere it will not be in direct sunlight or subject to constant spray.

5.3 Radiation Safety Considerations

The Model 410M contains two sealed radioactive sources. The radioactive material license is held by the customer at their facility under their local regulations governing fixed gauges. ETI handles source procurement, installation, and eventual disposal.

The sources are shielded by manually closing the source holder shutter. This operation should be performed in addition to following the site's approved safety and lockout procedures whenever personnel must work inside the radiation area.

ETI provides radiation safety training for plant personnel as part of the commissioning process and provides ongoing radiation safety support through its Radiation Safety Services program.

6. Integration with Plant Control Systems

6.1 SQL Stored Procedure (Preferred)

ETI's preferred integration method is direct SQL database access via a stored procedure. The DataView software records all measurement data to a local SQL database at one-minute intervals. ETI provides each customer with unique login credentials to call a SQL stored procedure from their plant control system, historian, or DCS to retrieve minute-by-minute measurement updates.

This gives plant systems direct access to the full data stream of ash content, belt loading, moisture, and heating value. ETI provides database connection details, table structure documentation, and assists with historian configuration during commissioning.

6.2 Analog Output

For plants that prefer a traditional analog signal, the 4–20 mA output maps the measurements to a standard current loop signal compatible with DCS analog input cards or PLCs.

6.3 Modbus TCP/IP

For plants with Modbus-capable DCS or SCADA systems, the Model 410M supports Modbus TCP/IP communication over a standard Ethernet network. The Modbus register map provides access to all measured parameters. ETI provides the Modbus register map documentation and can assist with DCS configuration during commissioning.

6.4 Alarm Outputs

The instrument provides configurable alarm outputs. Alarm setpoints are configured in DataView and can be changed by plant personnel without ETI involvement.

7. Operational Experience: Installation Examples

Installation Example

Minnkota Power Cooperative, Milton R. Young Station, Center, North Dakota

Application: Continuous elemental and ash analysis on four conveyor belts at Milton R. Young Station: two feeding the boilers directly and two building material stockpiles.

Coal type: North Dakota lignite from BNI's Center Mine.

Challenge: Lignite quality varies significantly between mining faces. Without continuous measurement, operators had to rely on shift-composite laboratory samples (results available hours after collection) to detect quality shifts. By the time a high-ash or low-BTU event was identified, the off-spec coal had already been burned, and the combustion effects had already occurred.

Installed equipment: Four Model 730 Full Stream Elemental Analyzers, each providing continuous readings of elemental composition, ash, moisture, belt loading, and calculated heating value.

Installation Example

Alpha Metallurgical Resources, McClure Prep Plant, McClure, Virginia

Application: Continuous coal quality monitoring on the conveyor feeding the stockpile used to load train cars.

Challenge: Maintain ash content across loaded train cars below contractual limits.

Installed equipment: One Model 410M Ash Analyzer providing continuous ash, moisture, weight and heating value measurements.

8. Choosing Between the Model 410M and the Model 730 FSEA

The Model 410M Ash Analyzer and the Model 730 FSEA both measure coal quality continuously and without contact on the conveyor belt. The right choice depends on the measurement objectives and the complexity of the application.

Criterion Model 410M Ash Analyzer Model 730 FSEA
Principal outputs Ash content (% dry-weight basis); moisture (calculated via density-based correlation); belt loading, heating value (calculated) Model 410M parameters plus full elemental profile (Si, Fe, Al, Ca, S, Hg, and others); direct PGNAA measurement
Derived parameters Calculated moisture content; Calculated heating value (from ash and moisture correlation) Calculated moisture, heating value, base/acid ratio, and other coal quality indices derived from elemental data
Measurement technology Dual-gamma transmission PGNAA plus integrated dual-gamma transmission
Radiation source Am-241 (low energy) + Cs-137 (high energy); two sealed gamma sources Californium-252 neutron source (PGNAA) + Am-241 and Cs-137 sealed gamma sources (integrated dual-gamma component)
Best suited for Ash monitoring; combustion control; consistent coal source Full quality characterization; emissions management; blending control; variable coal sources
Sulfur measurement Not available Yes; direct elemental measurement
Mercury measurement Not available Yes; direct elemental measurement of mercury present in the coal on the belt
Sensitivity to ash mineralogy changes Moderate; recalibration may be needed if mineralogy shifts outside the calibrated range Reduced sensitivity; recalibration may be needed if mineralogy shifts outside the calibrated range
Typical application Single-source utility coal; consistent lignite or bituminous supply Multi-source blending; cement; minerals; applications requiring sulfur or mercury data
Selection Guidance

If your primary need is continuous ash monitoring for combustion control and your coal source is relatively consistent, the Model 410M is the right instrument.

If you need sulfur or mercury data for emissions management, or if you blend coals from multiple sources with different elemental compositions, the Model 730 FSEA provides the full elemental profile needed for those applications. ETI engineers can review your application and recommend the appropriate instrument.

9. Conclusion

Ash content in coal is a major concern for power generation. It affects heat rate, slagging and fouling behavior, fly ash disposal costs, and particulate emissions. It is also a major concern for coal suppliers and processors as it affects their contractual obligations to produce an in-spec product.

ETI's Model 410M Ash Analyzer provides continuous full-stream measurements of ash and weight, along with calculated moisture and heating value. The ash measurement is a direct physical measurement rather than an inferred value from elemental data.

For facilities requiring elemental data as well as ash, the Model 730 FSEA combines the Model 800 PGNAA Analyzer with the Model 410M Ash Analyzer. This patented integrated system provides weight inputs needed for PGNAA analysis, while the elemental data further corrects the ash readings for higher accuracy.

ETI's Model 410M Ash Analyzer and Model 730 Full Stream Elemental Analyzer have been installed at power plants, cement plants, mine loadouts, and coal preparation facilities across North America, Europe, Asia, and Australia. Performance is site-specifically guaranteed using the site's own material, with evaluation in accordance with ASTM D6543. ETI engineers are available to review site-specific applications and will work with you to provide application-specific performance estimates.

Contact ETI

To discuss your ash measurement application or request a site-specific performance estimate, contact Energy Technologies Inc. at +1 865-927-9330 or info@energytechinc.com. Visit energytechinc.com for product specifications and additional technical resources.