A practical comparison of online elemental analysis and conventional laboratory methods for power generation and coal processing operations
Abstract. Coal-fired power plants and processing facilities have historically relied on periodic laboratory sampling in order to determine their total coal quality. This paper compares that approach to the use of a Prompt-Gamma Neutron Activation Analysis (PGNAA) device to provide continuous real-time measurement of the entire stream as it is transported on the conveyor. It examines measurement speed, analytical accuracy, cost of ownership, and the impact on real-time process decisions. Examples drawn from two North Dakota power plants are used to illustrate the operational differences between the two methods.
Coal quality, defined primarily by ash content, heating value (BTU/lb), sulfur, and trace elements such as mercury, directly controls fuel pricing, boiler efficiency, emissions compliance and maintenance costs in coal-fired power plants. The same quality concerns govern product value at mine-loadouts and prep plants.
The standard method of characterizing coal quality has historically been periodic sampling followed by laboratory analysis of the combined samples. Using this method, a mechanical sampler collects small portions of the coal stream at periodic intervals. The portions are combined, mixed, and crushed, with a smaller subset of the material analyzed in a laboratory. This approach is well-established and is accepted under ASTM standards. However, this approach has two major limitations: the laboratory results aren't available until long after the material has been processed, and variations in coal quality occurring between sample grabs go undetected.
Online, full-stream analyzers address these two limitations by measuring the entire material stream, including changes in coal quality between sampling periods, while providing the analysis information in real-time. This allows operators to react to coal quality changes and to make process adjustments to correct problems as they occur. This paper compares the two approaches, addressing measurement speed, accuracy and representativeness, cost of ownership, real-time decision-making capability, and regulatory/compliance utility.
Laboratory coal quality measurement is a multi-step process. A mechanical sampler installed on the belt line collects samples at periodic intervals. Cross-belt samplers sweep a cutter across the material, while falling-stream samplers collect material as it passes through a transfer point. Properly designed sampling systems are intended to collect representative samples of the material cross section. These periodic samples are combined into a gross sample which is typically collected once per day or shift and taken to the lab to be processed.
There, it is crushed and homogenized, with a small portion extracted for the actual analysis. Analysis is performed using calorimetry, combustion, X-Ray fluorescence (XRF), or wet chemistry methods, depending on the parameters being measured. The result represents the average composition of the sampled lot but does not reflect individual changes in coal quality between sample grabs. Furthermore, moisture changes during sample collection and preparation complicate as-received heating value calculations, particularly with high-moisture coals such as lignite.
The total time from the start of sample collection to the final result typically ranges from several hours for proximate analysis to one or two days for combined proximate/ultimate results.
PGNAA analysis measures the entire material stream and provides the results in real-time. The PGNAA analyzer is installed around the conveyor belt with the belt passing through the center of the device. A Californium-252 (Cf-252) neutron source emits fast neutrons which are converted to thermal neutrons by the system's moderator assembly. The thermal neutrons irradiate the full cross-section of the material stream and are absorbed by the atomic nuclei in the coal, causing the nuclei to emit gamma rays with energies characteristic of each element. A sodium iodide (NaI) scintillation detector absorbs the gamma rays, converting the absorbed energy into visible-light photons. The photons strike a photocathode in the detector unit's photomultiplier tube, releasing electrons which are accelerated with high voltage toward the anode. As the electrons move toward the anode, they strike a series of dynodes, releasing more electrons and thereby amplifying the signal. The resulting electrical pulse has an amplitude proportional to the gamma-ray energy deposited in the crystal. The detector electronics measure and classify these pulses by energy, producing a gamma-ray spectrum the system software analyzes to determine elemental composition. The Model 800 PGNAA component of the Model 730 Full Stream Elemental Analyzer (FSEA) system takes continuous measurements on a 6-second compilation cycle, with 1-minute averaged outputs reported to the operator and control system.
The neutron beam penetrates the entire depth of the material, catching the effects of layering and short excursions of higher or lower quality materials that periodic sampling grabs can miss. The inability of mechanical sampling to detect changes in coal quality between sample grabs creates uncertainty about the actual composition of the material processed, regardless of the accuracy of laboratory analysis.
There are three critical parameters PGNAA does not measure directly. They are ash content, moisture, and weight. A complete coal quality picture (including a calculated heating value) cannot be derived from PGNAA data alone.
ETI addresses this problem with a patented design combining the Model 800 PGNAA Analyzer with the Model 410M Ash Analyzer, forming the Model 730 Full Stream Elemental Analyzer (FSEA). The combined system continuously measures elemental composition, ash, and material weight while providing calculated measurements of moisture and heating value.
The Model 410M Ash Analyzer uses two sealed gamma sources, one high-energy source (Cs-137) and one low-energy source (Am-241), to continuously measure ash and weight. Moisture is a calculated value derived from a density-based moisture module. Heating value is then calculated from the ash and moisture measurements.
The Cs-137 high-energy gamma emissions are attenuated by the total mass of material on the belt. The Am-241 low-energy gamma emissions are also attenuated by the total mass but are more sensitive to the presence of the principal ash-causing elements of silicon, iron, aluminum, and calcium. The system uses the Cs-137 signal to normalize for bed depth while isolating ash content from the Am-241 signal. This allows accurate measurement across varying bed depths without requiring operators to maintain a consistent material profile.
The weight measurement allows the PGNAA system to convert relative elemental concentrations into absolute quantities. The detailed elemental data is then used to further correct the ash measurement.
The Model 730 FSEA has the unique ability to directly measure ash, weight, and elemental data and to provide calculated moisture and heating value. This provides operators the complete coal-quality picture needed for quality grading, sorting, blending, combustion optimization, and emissions management from a single online system.
The most noticeable difference between the two methods is the time between the material passing the measurement point and the operator receiving a result.
| Parameter | Laboratory Sampling | Online PGNAA (ETI Model 730) |
|---|---|---|
| Update frequency | Interval-based (site-dependent collection frequency) | 1-minute averaged outputs (6-second acquisition cycle) |
| Time to result | Site-dependent laboratory turnaround | ~1 minute from material passing the analyzer |
| Measurement basis | Discrete sample, periodic | Continuous, full stream |
| Operator action latency | Hours to days | Seconds to minutes |
| Integration with DCS/SCADA | Manual data entry or LIMS interface | Direct: SQL stored procedure (preferred), 4–20 mA, Modbus TCP/IP |
At a 500 MW power plant consuming 200 tons of coal per hour, a 4 hour lab turnaround means 800 tons of coal have been processed before the operator receives any indication from the laboratory that there was a problem. Quality excursions such as low heating value or high sulfur become historical events rather than actionable and correctible circumstances. When a boiler slags or a train car is out of spec, lab results will indicate why, but do not allow corrective measures to be taken. A common complaint where only lab analysis is used to measure coal quality is "we know what went wrong yesterday".
Additionally, because the lab results only represent the average composition of the samples, brief individual excursions in coal quality are often not seen at all and are therefore not resolved.
Laboratory accuracy is affected by the sampling process. ASTM D2234 and ISO 13909 define sampling procedures designed to minimize bias and mechanical sampling devices do a good job collecting representative samples. However, mechanical samplers can only take small portions of the material stream, can introduce particle-size bias, and the samples taken experience moisture changes during handling and storage. This results in a use of laboratory data which assumes a consistency and homogeneity of processed material which doesn't typically exist. Additionally, moisture losses in handling result in problematic heating value calculations.
The combined PGNAA and Dual-Gamma analysis provides analysis without the introduction of these sampling errors. The neutron and gamma ray beams irradiate the entire material stream, regardless of particle size, capturing the moisture content and the ever-fluctuating ash and mineral composition of 100% of the material that flows by. Excursions in coal quality between mechanical sampling times are captured and recorded instead of being missed. Layered materials that mechanical samplers may not reach are seen and accounted for. It should however be noted that very brief excursions can be diluted by the 1-minute averaging window.
ETI's Model 730 FSEA is performance evaluated in accordance with ASTM D6543. The system is calibrated using actual material samples from the customer's site vs. fabricated calibration standards made from stock materials. This material is sent to an independent certified lab for proximate/ultimate analysis, and the results are compared to actual system performance in order to calculate a system calibration. In PGNAA analysis, the presence of other elements can bias the readings of the element of interest. By using actual materials, the effects of elements not measured in the lab's proximate/ultimate analysis can still be accounted for in the final calibration. The final measurement accuracy is determined by the customer's material composition, but the measurement error will not exceed ETI's minimum quoted accuracy specifications.
PGNAA accuracy is affected by the thickness of the material in the neutron beam path. Without a weight bias correction, analysis values will fluctuate with bed depth although the quality of the material has not changed. Using a third-party mechanical scale requires the assumption that the weight on the scale is the same as the weight in the analysis zone and that the scale is properly calibrated.
ETI's Model 730 therefore dispenses with the need for an external scale and its resulting accuracy issues by employing the nuclear belt scale function of the Model 410M Ash Analyzer. The attenuation of the Cs-137 gamma emission is used to normalize the PGNAA elemental measurements for variations in material thickness. With this integration, the weight of the material in the analysis zone is known, not assumed, allowing process operators to run varying bed depths and to run material at intervals with no loss of analysis accuracy.
A coal-fired power plant typically incurs the following costs in operating a continuous sampling program:
The total cost varies by site depending on sampling frequency, laboratory rates, and whether the sampling lab is an in-house facility or at a third-party off-site location.
The ETI Model 730 installation involves an initial capital cost for the instrument, its installation, and its calibration. Ongoing costs include:
The online analyzer contains wear plates designed to carry the loaded conveyor belt through the instrument. The replacement period for the plates varies greatly depending on belt loading, speed, and alignment. We have extreme examples to illustrate this range. Some wear plates on relatively slow-moving cement conveyors have lasted 10 years while those on fast-moving, heavily loaded coal conveyors have lasted for three. A misaligned belt can cause immediate damage.
The degree to which laboratory sampling can be reduced is dependent on the site's contractual and regulatory requirements and therefore must be individually quantified. Some laboratory analysis is desired for comparison to analyzer results in order to confirm the calibration of the analyzer.
A more significant case for an online analyzer lies in cost avoidance. The analyzer provides immediate feedback, allowing plant or mine personnel to react to quality issues as they occur rather than retrospectively.
Consider the earlier example of a 500 MW coal plant consuming 200 tons per hour. Operating at over 6000 operating hours, and assuming a fuel cost of $130 per ton, a mere 1% improvement in heat rate represents a savings of $1,560,000 in annual fuel costs. While the actual savings at any site depends on operating hours, coal price, and the degree of improvement achievable, this illustrates the potential for an online PGNAA system to pay for itself in the short-term, with long-term savings in lower fuel costs and fewer outages.
Plant control systems are designed to accept real-time fuel quality inputs. ETI's preferred method of data transfer is direct access to the analyzer's SQL database, although analog 4-20mA outputs and Modbus TCP/IP are available. The ETI Dataview software records analysis results in the database at one-minute intervals. Plant control systems or historians can retrieve updated data via a database stored procedure using their own unique login credentials. It should be noted this is a read-only operation and does not permit changes to the ETI software or database.
Using this real-time data, the control system can adjust combustion air, burner tilt, and soot-blowing schedules in response to actual fuel quality rather than relying on a fixed setpoint based on historical averages.
This is particularly useful for plants using coals from multiple sources where quality varies by supplier.
Continuous sulfur reporting allows operators to monitor potential SO2 loading in real-time. When the sulfur level rises above limits, the operators can react by increasing scrubber reagent feed rates, adjusting the load, or switching to a lower-sulfur coal source. For mercury, this drives sorbent injection decisions. The continuous analysis results provided by the FSEA system allow a level of control not possible with delayed lab results.
Continuous FSEA measurements at mine loadouts and preparation plants allow operators to control the quality of coal piles, and to confirm the quality of material being loaded onto trucks or train cars. The ETI Dataview software includes a "truck" feature allowing operators to generate quality reports on individual truck or train car loads. This record may be used to satisfy contractual or regulatory requirements for shipment quality where the contract terms or regulations permit.
Application: Continuous coal quality monitoring for combustion optimization and emissions compliance at a lignite-fired power plant.
Installation: Four ETI Model 730 FSEAs are installed at Milton R. Young Station. Two are on conveyor belts feeding the boilers, and two are on conveyors building material stockpiles. All four provide continuous measurement of ash, heating value, sulfur, mercury, and base-to-acid ratio.
Challenge: Minnkota needed real-time coal quality data to optimize boiler combustion and to comply with emissions regulations, without pulling grab samples or interrupting conveyor operations. The lignite coal used exhibits significant quality variability, making periodic sampling unreliable for combustion control.
Installation use: The analyzers give operators quality information during operation rather than hours after the material has passed. Coal use is optimized while maintenance shutdowns due to boiler combustion issues have been slashed.
Application: Continuous coal quality monitoring for combustion optimization and BTU measurement at a lignite-fired power plant.
Installation: One ETI Model 730 FSEA is on the fuel-handling conveyor, providing continuous measurement of ash, heating value, sulfur, mercury, and elemental composition. Two ETI Model 510 BTU Meters are installed on the coal feeder pipes supplying the boilers.
Challenge: Otter Tail needed real-time coal quality data to support boiler combustion decisions and to monitor the heating value of coal at the point of combustion. These two measurement points required different instrument types. Periodic laboratory sampling produced unacceptable delays between material processing and quality confirmation, leaving operators without the ability to immediately control their process using the data.
Installation use: The Model 730 FSEA on the fuel-handling conveyor provides a continuous quality record for coal entering the plant, giving operators quality information in real-time. The Model 510 BTU Meters on the feeder pipes provide real-time heating value data just before the fuel enters the boiler, allowing operators to control feeders to obtain optimal fuel quality. Together, the two instrument types give Otter Tail continuous control of coal quality at both the plant intake and at the combustion point.
Online PGNAA results do not necessarily replace the sampling methods required by contracts or regulatory programs. Acceptance of FSEA results as authoritative depends on the contract terms and regulatory requirements which specify the sampling and analytical procedures governing settlement and reporting. However, online analyzers serve two important compliance support functions:
ETI's Dataview software archives time-stamped measurement data in its tSQL database and provides configurable alarm outputs, supporting documentation requirements and timely operational responses.
| Criterion | Laboratory Sampling | Online PGNAA |
|---|---|---|
| Measurement frequency | Interval-based (site-dependent) | 1-minute averaged outputs |
| Result latency | Hours (site-dependent) | ~1 minute from material passing the analyzer |
| Stream representativeness | Representative sample of the defined lot or collection interval | Full stream, continuous |
| Bias from sample extraction | Potential; managed through sampling-system design, maintenance, and verification | Avoided; no physical subsample extracted or prepared |
| Performance verification | Certified laboratory methods (ASTM) | Site-specific performance guarantee; evaluated per ASTM D6543 |
| Real-time DCS integration | Not available without LIMS interface | Direct (SQL stored procedure preferred; 4–20 mA, Modbus also supported) |
| Direct operating cost | Ongoing per-sample and labor costs | No reagents or mechanical sampling wear parts; source replenishment ~30 months |
| Combustion optimization | Delayed feedback; usefulness depends on turnaround and material transit/storage time | Earlier warning where placement and process timing permit |
| Emissions excursion response | Delayed; usefulness depends on turnaround and material transit/storage time | Earlier warning within reporting interval |
| Contract/regulatory settlement | Accepted per applicable contract and regulatory requirements | Does not automatically replace required methods; acceptance is contract/program-specific |
Laboratory sampling and online PGNAA analysis with the Model 730 FSEA serve different purposes. Laboratory analysis remains the standard for contract settlement, regulatory reporting, and initial calibration of the online instrument.
Online PGNAA analysis is the preferred tool for process control, combustion optimization, and real-time emissions management. It is optimal for any application where acting on a measurement is critical before the material has already been burned, shipped, or blended.
The practical case for online analysis rests on the timeliness of the information it provides. Continuous quality data enables blending and combustion decisions that delayed periodic laboratory results cannot support. The financial value of that timeliness is shown in the effects of coal quality variability, the need for process flexibility, and the degree to which combustion control is currently limited by the timely availability of fuel quality data.
ETI's Model 730 Full Stream Elemental Analyzer has been installed at power plants, cement plants, mine loadouts, and coal preparation facilities across North America and Europe. Performance is site-specifically guaranteed using the site's own material, with evaluation in accordance with ASTM D6543. ETI engineers are available to review site-specific applications and will work with you to provide application-specific performance estimates.