Model 520

Multi-Gamma Slurry Analyzer

The ETI Model 520 is a multi-energy gamma online analyzer that measures ash content and density of a slurry as it is transferred through piping in real time, without sampling or preparation of any kind.

ETI Model 520 Multi-Gamma Slurry Analyzer pipe-mounted sensor assembly

Turn continuous slurry data into better process decisions

Know your slurry quality in real time

Continuous ash content and density data, updated every 60 seconds, without pulling a single sample or interrupting the slurry flow.

Catch process upsets immediately

See changes in slurry composition as they happen, not after a lab report reveals a problem hours later.

No contact, no downtime

The analyzer clamps to the outside of the pipe. Nothing touches the slurry stream.

Applications

Coal Preparation Plants

Monitor slurry ash content and density in real time to optimize washing circuits and maximize clean coal recovery, without interrupting the slurry flow.

Dense Media Circuits

Continuously track slurry density to maintain precise media-to-coal ratios and improve separation efficiency across the full process stream.

Tailings Management

Measure tailings slurry ash and density in real time to support environmental compliance, process optimization, and accurate reporting.

Pipeline Transport

Ensure consistent slurry quality during long-distance pipeline transport of coal or mineral slurries, with continuous ash and density monitoring.

ETI Model 520 Multi-Gamma Slurry Analyzer installed on slurry pipeline at coal preparation plant

Case Study

Coal Preparation Plant: Continuous Slurry Monitoring

A coal preparation plant installed an ETI Model 520 Multi-Gamma Slurry Analyzer on their dense media circuit to continuously monitor slurry ash content and density. The analyzer enabled operators to optimize washing circuit performance and maximize clean coal recovery in real time, without interrupting slurry flow or relying on periodic lab samples.

Request a Quote

Key Benefits

Continuous measurement: Updated every 60 seconds; no sampling delay, no manual preparation.
Measures ash and density simultaneously: Two parameters from a single non-contact measurement through the pipe wall.
No contact with the slurry: Clamps to the outside of the pipe; no wear, no plugging, no process interruption.
Low maintenance: No moving parts, no wear components. Periodic recalibration not required.
Seamless plant integration: Analog, digital, Modbus TCP/IP, or SQL; connects to any DCS or plant information system.
Automatic load compensation: Corrects for slurry flow rate variations to maintain accurate readings under changing process conditions.

How It Works

The Model 520 uses the principle of differential gamma attenuation: two radioactive sources emit gamma radiation at different energies through the pipe wall and slurry. Because different elements attenuate gamma energy differently based on their atomic number, the detector response can be interpreted as a change in the ratio of element groups; yielding ash content and density simultaneously.

1

Dual Gamma Sources

Two sealed radioactive sources (Am-241 and Cs-137) are mounted in a shield clamped to the pipe. Both energy levels irradiate the full slurry stream simultaneously.

2

Selective Attenuation

The two source types are attenuated differently as gamma energy passes through the slurry. Cs-137 is attenuated only by the total mass of material in the pipe. Am-241 is attenuated by both the total mass and the principal ash-causing elements; silicon, iron, aluminum, and calcium. Using the Cs-137 signal to normalize for pipe loading, the analyzer isolates ash content from the Am-241 reading; so accurate measurement does not depend on maintaining a consistent slurry flow rate.

3

Energy-Sensitive Detection

A radiation energy-sensitive detector mounted on the opposite side of the pipe measures the transmitted gamma spectrum at each energy level.

4

Automatic Load Compensation

The analyzer's automatic load compensation module corrects for variations in slurry flow rate and pipe loading, ensuring accurate ash and density readings regardless of process fluctuations.

5

Real-Time Data Output

The Data Acquisition Unit processes detector signals every 3 seconds and outputs ash content and density to plant control systems via analog, digital, Modbus TCP/IP, or SQL database.

Model 520 on Slurry Pipe
ETI Model 520 Slurry Analyzer pipe-mounted sensor assembly

Source and detector assembly clamped to opposite sides of the slurry pipe

Technical Specifications

U.S. Patent # 7,243,414B2

System Components

The analyzer system consists of:

  • Model 520 Multi-Gamma Analyzer (MGA)Fixed nuclear gauging device using two sealed radioactive sources depending on application. Source shield mounts on the pipe and collimates a conical fan radiation beam through the slurry. Energy-sensitive detector mounts on the opposite side of the pipe. Total weight: 350 lbs. (≈159 kg).
  • Model 900 Data Acquisition Unit (DAU)NEMA 4 electronics enclosure with fully digitized data acquisition and control electronics, uninterruptable power supply (UPS), detector temperature control and monitoring, I/O modules, circuit breakers, and managed network switch. Wall-mountable. Dimensions: 36 in. H × 30 in. W × 13 in. D (91 × 76 × 33 cm). Weight: 170 lbs. (≈77 kg). Max distance to analyzer: 328 ft. (100 m).
  • Interconnecting CablingComplete set of signal cables, power cables, and special connectors between the MGA and DAU. Maximum cable length: 328 ft. (100 m).
  • ETI DataView Software PackageMonitors all aspects of the analyzer: spectral shape, count rate, resolution, dead time, detector temperature, calibration parameters, and final data. View data from 3-second measurements to daily totals with configurable tabular and graphical displays.

Measured Parameters

  • Ash
  • Density

Data Outputs

  • Analog Outputs4 channels, configurable for 0-20 mA or 4-20 mA signals
  • Digital Outputs4 channels, configurable for 24 VDC signals
  • Modbus TCP/IPStandard industrial communication protocol
  • SQL DatabaseDirect database access for Plant Information systems

Radioactive Sources

IsotopeActivity
Am-241300 mCi
Cs-13720 mCi

Plant Integration

Readings are taken every 3 seconds and averaged over 60 seconds. Output is available via analog connections or direct database access for seamless integration into plant control systems. ETI DataView client software provides real-time dashboards, historical trending, and batch reporting on any plant workstation.

One year of service included

Every ETI system ships with one full year of support, unlimited phone, email, and remote VPN access, plus one scheduled site visit for inspection, calibration, and NRC-required leak tests.

Ready to optimize your process?

Contact our engineers to discuss how the Model 2000 can improve your operation.

Related applications:Coal QualityMinerals & Mining